Weatherking Furnace Reviews

Showing 16-20 of 52 reviews

"Home owner"

1.0 rating
Very Unsatisfied

I had a weather king Installed 2 years ago 2008 wow, what a piece of garbage. when it kicks on the air is cold,when it's running the heat is luke warm and when it shuts down the air is cold. does anybody know what is wrong with this white elephant?

kevin

pittsburgh pa.

"Trash"

1.0 rating
Very Unsatisfied

This furnace worked just 2 years

B. A.

Florida

"You People are Crazy"

5.0 rating
Very Satisfied

Hi! My name is Jon, owner and president of AAA Aire Heating and Cooling LLC in Kansas City and I have a few answers to all the problems that you people are having. One, if you have replaced a motor in it twice, try changing the blower capacitor. Your board will never go bad due to a blower motor. Also, if you have been getting water into the bottom of the furnace that is why it keeps going bad. You always have to replace the capacitor when you change a blower motor, a fan motor in a condensing unit, replacing a contractor in a condensing unit or a vent motor. Find a new service man! Alot of people don't know what a Weather King funace is. Weather King is a Rheem funace. They also make Ruud, Sure Comfort and Remmington. Im a Sure Comfort Dealer and i've never have one problem. G Ham, if you back up heat is not coming on, you have a bad t-stat or outdoor t-stat. Have a Honeywell 8000 touchscreen with outdoor sensor installed. If you dont have at lease 8 ran to the t-stat, you have to install a Honeywell IAQ or a wireless system. It has nothing to do with you furnace. Find a new Service man! Also your heat pump should be set to shut off at 30 the max, I like 35. Find a new service man! D. Butera, Don't put in a carbide ignitor. Replace it with a nitride igniter in. It will Last Longer. Get a new service man! D. Miller, If you have a 90% funace or above you have a 10 year warranty. That is if you service man registered your funace when it was installed. All 90% and above funaces and any R-410A equipment has to be registered online to have a 10 year warranty. If you don't do this the equipment will only have a 5 year warranty Find a new service man! Charlie C., the furnace was wired up wrong! Find a new service man! Janet Schminkey, The parts that you have had to replace, are parts the just go bad on all funaces. All the parts that are in your funace is the same that is in mine and everyone's furnace. If they say that its not they are a lier. There are only a few different companies that make this stuff like, Honeywell, Johnson Controls and White Rogers. THEY ARE MAN MADE. Find a new service man! If you people have been listining you would find a common problem to most of these problems. FIND A NEW SERVICE MAN! That has a big part on if you stay cool in the summer or warm in the winter. If you have any ?'s about this please call. 816-878-7887 and I will be glad to speak with you.

Jon Moon

Kansas City

"Home owner"

1.0 rating
Very Unsatisfied

I replaced the motor on it twice and now just found out that the motherboard is bad and has to be replaced. This unit is junk and should be in a junkyard. I have a unit doing my 1st floor since 1960. No problems. They don't make them like they used to anymore. What happened to quality control?

R. Imbrogno

"Junk"

1.0 rating
Very Unsatisfied

All I can say is junk all the money I put in fixing this. I could have bought a top line furnace.

Brad

HVAC Brands

Learn more about your home's heating and cooling system with our guides, how-to's, FAQ's, tips and more.


Ready to get a quote from an HVAC contractor?

Let us know what type of service you need and we can connect you with a certified local HVAC contractor.

Please enter a valid name

Please enter a valid phone number

Please enter a valid zip code

There are no dealers in this zip code.

Please enter a valid email address

Please select repair or replace

Please select heating, cooling or both