Lennox Elite Furnace Overview

Lennox Elite furnaces are a series of gas and oil furnaces currently in production. Five gas models are available, ranging from two high-efficiency models, the EL296V and the EL296E, with an AFUE rating of ninety-six to the EL280, which has an AFUE of eighty. The EL296V and the EL296E are both Energy Star-certified. Single-stage and two-stage heating models are available in the Elite series. One model, the ELO183, is listed as an oil furnace in the Elite series, with an AFUE of eighty-three.

Furnace Filters for the Lennox Elite

Air Flow ConfigurationCabinet WidthFilters
Upflow / Horizontal17.5″16x25x1 (bottom)
Upflow / Horizontal21″20x25x1 (bottom)
Upflow / Horizontal24.5″24x25x1 (bottom)
Upflow / HorizontalAll16x25x1 (side)

Questions about this model?

Consumer Reviews of Lennox Elite

2.5

  • Very Satisfied
    6
  • Somewhat Satisfied
    2
  • Neutral
    1
  • Somewhat Unsatisfied
    3
  • Very Unsatisfied
    12
  • #10 of 29 Lennox Furnace
  • 33.33% of customers recommended

Read Reviews of Other Lennox Products

Find ratings and reviews for Lennox Air Conditioners, Boilers and more

Read Reviews

Top 10 Furnaces

See who made our list of the best Furnaces of 2020.

See the Top Products

Find a Certified Heating & Cooling Professional In Your Area

Contact a top-rated local expert to help with all of your home's HVAC needs.

Lennox Elite Furnace Reviews

Showing 21-24 of 24 reviews

"Carrier Furnaces"

1.0 rating
Very Unsatisfied

Bought two Carrier 58ss furnaces, along with two Carrier ACs, and two Carrier Electronic filters in 1982. Had trouble from the beginning with the furnaces and air cleaners. Furnaces had to have circuit boards repaired, replaced numerous times, as well as fan motors replaced, etc. ACs were another story… rock solid, and we have summers with over 100 degrees for weeks at a time here in the midwest. 27 years on the ACs until one died this month. Not bad! The furnaces are another story… Finally replaced the Carrier furnaces with Lennox G50s in 2004 when one of the Carriers died for the last time. Had one service call on one of the Lennox furnaces in the interim and that was such a simple fix that the service tech incorporated it into a seasonal tuneup charge. Nice! Short story, Long… Carrier: good ACs, poor furnaces. Lennox: good furnaces… do I dare replace the ACs with another Carrier product or take a chance on Lennox ACs/Heat Pumps?

"Angry and disatisfied"

1.0 rating
Very Unsatisfied

We bought a Lennox Elite Series 11 yrs. ago we have replaced the ciruit board twice now, the ignition switch once, and had the fan repaired, I even have had a certified contractor come and just clean and oil it because I am so afraid of freezing another winter. It is so noisy when it is running it sounds like a jet plane taking off. It is a piece of crap I will never purchase another Lennox and do not recomend it to anyone. I agree with the person who commented about Lennox should stand behind their product and give some compensation back in return. Next repair it is gone.

Salt Lake City, UT

"Mr"

1.0 rating
Very Unsatisfied

Of23 Lennox oil furnace sounds like an aircraft is taking off in the house. Installed two days ago, can not sleep at night Piece of junk

Montreal, QC, Canada

"Title"

4.0 rating
Somewhat Satisfied

I had a Lennox g60dxv installed in March of 2005. I had contracted for the smallest unit (70,000btu) but they installed the next size larger, When I questioned the salesman he said he substituted the larger unit so it would never go into the second stage. hah! I think it was because the larger cabinet fit my installation easier. I made them remove the oversized unit and replace it with the proper sized unit. I had the free service after the first year and was less-than-impressed by the technician. He was certainly likeable and seemed to know what he was doing but I had to ask him to check the gas pressures and then fix the battery clip on his manometer. He did not clean the heat exchanger, which Lennox suggests be done at annual check. About a month into the next heating system the unit failed without any diagnostic lights pointing to the problem. I found the draft switch connection plugged with corrosion and upon cleaning it worked okay. This same thing happened again a couple of weeks later but since the second cleaning it has been working fine the rest of the season. The installing company has been in business since 1922 so mere longevity in business is no guarantee of either quality installation or service.

Seattle Suburb

Other Elite Reviews

An HVAC installer writes on the hvacsite.com forum about a problem with his personal Lennox Elite furnace. He is having trouble with the fan turning on and off properly; the experts at the forum agree that the problem is probably a faulty electrical board.

Another post on hvac-talk.com points out the fact that most HVAC forums highly recommend Lennox and Carrier products. Installers often say a homeowner cannot go wrong with these companies, and they should compare warranties, rebates, and tax credits to make a decision.

A writer on diychatroom.com has inherited a Lennox Elite furnace with the purchase of an existing home. He does not believe it has been serviced, and he is having problems with fan noise and the thermostat. The contractors online direct the homeowner to clean several parts on the furnace, and then see what happens. The post makes a good point about regular service check-ups.

Question and Answer

Question:

I need the meaning of the diagnostic light codes on the control board of a Lennox Elite Series

Answer:

The answer may vary slightly by model number. Here are the error codes for the Lennox EL195:

  • Off: No power to control or board fault detected Heartbeat: Control powered − displayed during all modes of operation if no errors are detected
  • 1: Reverse Line Voltage Polarity
  • 2: Improper Earth Ground
  • 3: Burner failed to light, or lost flame during heat demand
  • 4: Low Flame Signal − check flame sensor
  • 5: Watchguard − burner failed to light, exceeded maximum number of retries or recycles.
  • 6: Ignitor Circuit Failure − not available on this control
  • 7: Primary or Secondary Limit Open or Watchguard Mode − Limit Switch Open longer than 3 minutes
  • 8: Rollout Switch Open
  • 9: Pressure Switch failed to close or opened during heat demand 10 Watchguard − Pressure Switch opened 5 times during one heat demand 11 Pressure Switch stuck closed prior to activation of combustion air inducer
  • 10: Flame Sensed without gas valve energized
  • 11: Low Line Voltage

Notes:

  • A “Heartbeat” is indicated by a “Slow Flash” − 1 sec on 1 sec off, repeating
  • Error codes are indicated by a “Rapid Flash” − the LED flashes X times at 1/2 sec on 1/2 sec off, remains off for 3 sec, then repeats
  • Last 10 error codes are stored in memory − To recall, press and release button, most recent will be displayed first, LED off for 3 sec, then next error code is displayed, etc. To clear error codes, depress and hold button longer than 5 seconds.

Lennox Elite Model Numbers

The Elite is available in different models which vary in efficiency and capacity.

Model Number AFUE BTUs per Hour
G61MP-36B-071-* 95 66,000
G61MP-60C-091-* 95 88,000
G61MP-60C-091-** 95 88,000
G61MP-60C-111-* 95 110,000

Elite Warranty

The Lennox Elite series offers a five year warranty on parts and ten years for the compressor. Depending upon the model, the heat exchanger carries a twenty-year or limited lifetime warranty. Lennox also offers an extended warranty, available for purchase.

HVAC Brands

Learn more about your home's heating and cooling system with our guides, how-to's, FAQ's, tips and more.


Ready to get a quote from an HVAC contractor?

Let us know what type of service you need and we can connect you with a certified local HVAC contractor.

Please enter a valid name

Please enter a valid phone number

Please enter a valid zip code

There are no dealers in this zip code.

Please enter a valid email address

Please select repair or replace

Please select heating, cooling or both