Bryant Evolution Plus 95s Furnace Overview

The Bryant Evolution Plus 95S furnace is a variable-speed condensing gas furnace that can achieve an AFUE rating of up to 95 percent. The Evolution series is Bryant’s top line of furnaces; this series was included in the Evolution lineup as late as 2010. Bryant reports that the Evolution series provides strong humidity control for the homeowner and operates at low decibel levels. The Fan On Plus feature allows the user to adjust continuous fan speeds. The Evolution controls feature a fully-programmable thermostat that, with certain options, can even be controlled away from home by a cell phone.

Furnace Filters for the Bryant Evolution Plus 95s

Air Flow ConfigurationCabinet WidthFilters
All16-(height-of-filter-cabinet)”1 16x25x3-4
filter
All17-1/2″1 16x25x3-4
filter
(side air return)
1 16x25x3-4
filter
(bottom air return)
All20(height-of-filter-cabinet)”1 20x25x3-4
filter
All21″1 16x25x3-4
filter
(side air return)
1 20x25x3-4
filter
(bottom air return)
All24(height-of-filter-cabinet)”1 24x25x3-4
filter
All24-1/2″2 16x25x3-4
filters
(side air return)
1 24x25x3-4
filter
(bottom air return)

Questions about this model?

Consumer Reviews of Bryant Evolution Plus 95s

1.8

  • Very Satisfied
    2
  • Somewhat Satisfied
    0
  • Neutral
    0
  • Somewhat Unsatisfied
    1
  • Very Unsatisfied
    9
  • #8 of 21 Bryant Furnace
  • 16.67% of customers recommended

Read Reviews of Other Bryant Products

Find ratings and reviews for Bryant Air Conditioners, Boilers and more

Read Reviews

Top 10 Furnaces

See who made our list of the best Furnaces of 2020.

See the Top Products

Find a Certified Heating & Cooling Professional In Your Area

Contact a top-rated local expert to help with all of your home's HVAC needs.

Bryant Evolution Plus 95s Furnace Reviews

Showing 11-12 of 12 reviews

"Very good usually"

5.0 rating
Very Satisfied

I actually own the 355cav60100 (Plus 95s Evolution system) installed in a downflow configuration. Not sure what the difference is in the cav and mav but the cav wasn’t available on the drop down list. I also got the Bryant humbblfp1418a whole house humidifier with the Bryant Legacy Touch and Go thermostat. The furnace/humidifier has been a good package for nearly two years – I got it April before last so I’ve only used it for one complete winter. It maintains a very nice temperature without the large fluctuations of my last forced air furnace. While this makes for excellent comfort, it means the furnace has to run a lot – sometimes, a new cycle will start before the blower even shuts off from the last cycle. The humidifier is worth it as it tames the nasty static electricity we usually have in this dry Colorado air. It does use hot water though, so that costs a little extra. And it has a small fan. When the furnace is raising the house temp from the overnight or away setting, it’ll run on low for 15 minutes or so, then kick into high till the temp is slightly above the set point. While this furnace is much quieter than my last furnace (it runs on low or medium most of the time), it can still make some noise on high. Sometimes it even kicks into high after the set temp has been reached – strange. The main relay took a little getting used to also – it’s mounted on metal and makes a fairly loud noise when it engages – it can startle on a quiet morning. I put a rubber pad under it which helped some. I don’t get regular service from the hvac company. I change the filters and humidifier pads myself. I hadn’t had any trouble at all with this setup until last week. The temperature was coming up early in the morning, before I had gotten out of bed. I heard the furnace shut off abruptly only about 1/2 hour after it started – it usually takes about 1.5 hrs to raise the morning temp. I found that the control board and surrounding area was wet and some switches had shorted out, shutting down the operation. The humidifier is located above the control board in the ducting and for some reason I still don’t understand, water had come from above, down the ducting and onto the equipment below. I dried out the board with a hair dryer, reset the trouble codes and it started working normally. It did the same thing the following morning while I wasn’t watching again. It wouldn’t do it while I was watching, although I couldn’t see inside the duct with the furnace in operation anyway. All I ended up doing is turning the water faucet valve for the humidifier down to only 1/4 turn open. I had watched the dump line from the humidifier through numerous cycles and noticed a surge of water in the line one time. Maybe the solenoid valve does something weird. Haven’t had any trouble in days so I’m keeping my fingers crossed. I put a loose cover over the control board so it doesn’t get sloshed if this happens again. I’m happy with my purchase and would buy it again. I think I got a pretty good deal as the dealer was trying to get rid of it, I guess to make room for newer models. I hope I don’t end up needing some expensive service.

Grand Junction, CO

"Serial #4909A01441"

1.0 rating
Very Unsatisfied

I am resubmitting this because it submitted before I could type in my email address. Our family has ben unhappy with this furnace since the first day and it has only gotten worse. If we we’re rich we’d have it ripped out and a different brand put in, but were not so we have to live with it. We set it for 62 at nite, while everyone is getting ready in the morning it’s set for 67. As soon as they leave I turn it back to 62 so I don’t have to listen to it run all day. I simply put on another sweater and have a blanket for my legs. When the kids get home from school I turnit back to 67 until we go to bed at 9:30 them it goes back down to 62, then we start all over again. The problems are that it clicks between 12 and 20 like a lighter is trying to work before it turns on, then when it does turn on, it sounds like there’s a car with a bad tail pipe in our driveway or we compare it to hiring someone with a truck and scoop on to come and plow our driveway. The old furnace was the size on a small car, but it heated the house just fine and the only was we knew it was on was my going to a heat vent and feeling to see if anything was coming out. At the time something had happen to the ball bearings tht Schweickerts said was to expensive for us to repair so they recommended getting a new furnace. We knew it was old and trusted Schwickerts to be telling us the truth, we don’t feel that way now. We would NEVER recommend this company or furnace brand to any friends or family members, we really wouldn’t even recomend to someone we didn’t like.

Mankato, MN

Other Evolution Plus 95s Reviews

A homeowner asks for a comparison of the Bryant Evolution Plus 95S to a similar Trane furnace on gardenweb.com, as these are being proposed by an installer. The experts respond that while both models are good, the Bryant furnace is a great choice, especially with the Evolution programmable thermostat. The contractors stress that the customer should ask for a load calculation, so the proper size unit can be installed for the size of the home.

Another post on gardenweb.com reveals an owner asking if her Bryant Evolution furnace should be cycling on and off frequently within one hour. An expert answers that there should be a setting on the Evolution thermostat to regulate cycling per hour.

A Bryant Evolution furnace owner posts on hvac-talk.com about an error message he receives on his unit. A local contractor told him it may be caused by back pressure from high outdoor winds. The online experts say that is doubtful, and suggest the consumer check for obstructions in the lines, as well as the possibility that the low pressure switch could be faulty.

Question and Answer

Question:

What does error code 42 mean?

Answer:

An error code 42 is an inducer motor fault. The inducer motor may need to be serviced, or it might need to be replaced. This type of job usually requires the skills of a

heating contractor.�

This Bryant troubleshooting guide breaks down the error codes.

Bryant Evolution Plus 95s Model Numbers

The Evolution Plus 95s is available in different models which vary in efficiency and capacity.

Model Number AFUE BTUs per Hour
355CAV042060* 95 60,000
355CAV042060** 94 60,000
355CAV042060*** 94 60,000
355CAV042080* 95 80,000
355CAV042080** 92.3 80,000
355CAV042080*** 94.7 80,000
355CAV060080* 95 80,000
355CAV060080** 92.3 80,000
355CAV060080*** 94.7 80,000
355CAV060100* 95 100,000
355CAV060100** 93.5 100,000
355CAV060100*** 95 100,000
355CAV060120* 95 120,000
355CAV060120** 93.8 120,000
355CAV060120*** 93.8 120,000
355CAV060C080** 95 80,000

Evolution Plus 95s Warranty

Bryant offers a limited lifetime warranty on the heat exchangers for the Evolution Plus 95S, and the entire furnace is guaranteed by a 5-year limited warranty.

HVAC Brands

Learn more about your home's heating and cooling system with our guides, how-to's, FAQ's, tips and more.


Ready to get a quote from an HVAC contractor?

Let us know what type of service you need and we can connect you with a certified local HVAC contractor.

Please enter a valid name

Please enter a valid phone number

Please enter a valid zip code

There are no dealers in this zip code.

Please enter a valid email address

Please select repair or replace

Please select heating, cooling or both